ENERGY SAVING IN FOOD PACKAGING
Increasing energy and raw
material costs, along with a growing sensitivity
toward environmental issues, have led printing
companies to seek new ways to obtain energy
savings in order to reduce management costs and
stay competitive on the international markets.
During the exsiccation process of
the inks on the printed material, a lot of
energy is required to heat up the air inside the
ventilation system of each printing machine.
Through an automatic air recirculation control
system, it is possible to recycle most of this
hot air and send it back as a inlet fresh air in
the ventilation system of the printing machine.
This automatic air recirculation
system drastically reduces the energy costs
associated with the air heating system (Heat
exchangers).
The automatic air recirculation
system offers key benefits like energy saving,
air volume reduction resulting is saving in
investment required to solvent recovery, and
increased safety inside the press room.
LEL MONITORING
SYSTEM:
The flammable properties of the
solvents and the high temperatures inside the
ventilation system of any Laminating, Flexo or
Rotogravure printing machine, can create
dangerous risk of explosions. In order to avoid
these dangerous conditions, the solvent
concentration inside the ventilation system must
be checked by a LEL Monitoring System and must
be kept below then the 50% of its Lower
Explosion Level (UNI EN 1539). A LEL Monitoring
System is an analytical system able to check and
control the solvent concentration inside the
drying stations during any printing or
laminating process.
AUTOMATIC AIR RECIRCOLATION CONTROL SYSTEM:
Actually, on the printing or
laminating machines, there are two different
types of ventilation systems: ventilation system
without air recirculation system, usually
present on old printing or laminating machines
and ventilation system with manual or automatic
air recirculation system, generally already
present on new printing or laminating machines:
THIS ENERGY SAVING ESTIMATION IS
BASED ON A SINGLE PRINTING ELEMENT:
Air recirculation
percentages
0% 50% 90%
Inlet air
flow m³/h
5.000 5.000 5.000
Inlet air
temperature °C
20 20 20
Drying
temperature °C
70 70 70
Heat exchanger DT
°C
50 32 17
Energy required to heat up
1m³ of air for given
DT Kcal/m³
14,4 8,69 4,53
ENERGY SAVING
0%
30% 60%
Unfortunately, it is very
difficult to establish the total investment on
this automatic air recirculation system, because
all the printing or laminating machines on the
market have different configurations and
characteristics.
In some machines, which is
already present a manual air recirculation
systems, it will be possible to obtain the
automatic air recirculation system, just by
adding a LEL monitoring system and some
pneumatic actuators, but unfortunately, in some
older printing machines, some adjustments on the
ventilation system will be absolutely needed.
In order to establish the total
project investment, a technical inspection by
our specialized technicians will be absolutely
required. After this technical inspection, we
will be able to estimate the total project
investment, the energy saving and also the
payback time based on the yearly energy saving.
Through our LEL monitoring system
and through our automatic air recirculation
control system, the printing companies can save
a lot of money wasted on the air heating system
and they can also obtain many others benefits
and advantages:
- More
safety inside the work shop, because monitoring
and keeping under control the solvent
concentration inside the ventilation system,
avoids dangerous risk of explosions.
-
Lower investments on air treading systems,
because these investments are partially related
to the quantity of air to be treated, through
our systems, we reduce the volume of the air in
discharge (from 40 to 60%) and we also reduce
the expensive investments on the air treading
systems (number and dimension of the “absorbers”
with active carbon).
NIRA SUPPLIES THE FOLLOWING
PRODUCTS AND SERVICES:
-
Free consultation
-
Plant inspection
- Studies of the ventilation
system
- Detailed quotation
-
Energy saving estimation
-
Construction drawings for
mechanical adjustments of the ventilation system
-
LEL monitoring systems and
installation and automatic air recirculation
control systems and
installations
-
Contract maintenance |